Auto Charging System for AGV Battery System
Ability and Composition


Function Automatic Operation Automatic battery exchange makes it possible to operate production lines on a 24-hour continuous, fully automated basis.
Manual Operation

When charger mode is manual mode, It is used to equal charging and float charging for active charging.

Composition Input Transformer
Rectifier
Protection Equipment
  • Input Circuit : MCCB Attached
  • Input Over Current : Fast open Fuse Attached
  • Output Over Current : Current Control Circuit
  • Output Over Voltage : charging break equipment
Measurely Instrument
  • DC VOLT METER (DIGITAL)
  • DC AMP METER (DIGITAL)
Control Unit
  • AUTO/MANUAL MODE SWITCH
  • AGV/CHARGER MODE SWITCH
  • CHARGER START BUTTON
  • CHARGER STOP BUTTON
  • ERROR RESET BUTTON
  • BUZZER STOP BUTTON
  • FLOAT VOLT ADJ. / EQUAL VOLT ADJ. / CURRENT ADJ.
  • AUTO CHARGE TIMER
  • MAUAL CHARGE TIMER
Condition Indication Unit
  • POWER ON LAMP
  • POWER OFF LAMP
  • AUTO MODE LAMP
  • MANUAL MODE LAMP
  • AGV MODE LAMP
  • CHARGER MODE LAMP
  • CHARGER START LAMP
  • CHARGER STOP LAMP
  • EQUAL LAMP
  • FLOAT LAMP
  • CHARGER COMPLETE LAMP
  • CHARGER ERROR LAMP
  • BATTERY TIME ERROR LAMP
  • SPARE LAMP
Alarm Unit
  • CHARGER ERROR :
    Fuse, Over voltage / low voltage, Fan error, Temperature error
  • BATTERY TIME ERROR:
    Battery Error, Charging coupler Error
Charging Coupler

This charging coupler is received the power unit from charger. And supply the charging power to the AGV.

  • Charging Unit: It has a driving motor and charging pin to the automatically charging
  • PLC: It is a Program Logic Controller for the operatior of charger
  • 8 Bit Sensor: It is sequence for the order of charging start and complete.
  • Control Panel: AUTO/MANUAL MODE SWITCH, START/STOP BUTTON, ERROR RESET BUTTON, CONDITION DISPLAY LAMP, ERROR LAMP